| Technical
Specifications - i
Q QualiCenter |
iQ-QualiCenter
goes beyond mere evenness measurement providing total quality
measurement and analysis of yarn, sliver and roving. Critical
quality parameters such as count, hairiness and nep classification
of yarn are determined simultaneously. Long term trends and
comparative assessment of quality can be easily carried out.
The parallel measurement of yarn, roving/sliver saves not
only the test time and manpower cost but quickens the corrective
response time.
|
 |
| Application
Results |
| Numerical
Results |
Evenness
Unevenness U% (within the range 0.5 to 40 %)
Coefficient of Variation CV% (within the range 0.5 to
40 %)
Coefficient of variation at different cut lengths (1,
3, 10, 50 or 100m and for the inert and half-inert modes)
Index of Irregularity (Ratio of the actual unevenness
to the ideal unevenness with staple fibre material)
Imperfections:
Thick places : +35%, +50%, +70%, +100%
Thin places : - 30%, - 40%, - 50%, - 60%
Neps : +140%,+200%,+280%,+400%
(Results at the above sensitivity levels can be viewed
or printed out simultaneously)
Relative Count (Percentage count variation of the tested
material between samples in a series of measurements
with conversion of the mean value to 100%)
Maximum and minimum values for mass at cut lengths 1,
3, 10m and for the half inert cut lengths
|
| |
Hairiness (Optional with Hairiness Module)
Hair length Distribution (Hair Count) from 3mm to 12mm
Hairiness Index Value (with the optional Hairiness Tester)
Standard Deviation of Hairiness (with the optional Hairiness
Tester) |
| |
Nep Classification (Optional with Nep
Module)
Nep classification into Process Nep, Seed coat Nep |
| |
Actual Count (Optional with Auto count
Module)
Linear Density (count) For Yarn, Roving and Sliver |
| |
Statistical
Block for all the numerical parameters
(Containing Mean Value, Standard Deviation, Coefficient
of Variation, Confidence Range, Median and Premier Statistics
%) |
| Graphical
Results |
Applicable
for Evenness & Hairiness as mentioned
Normal diagram
Cut Length Diagram
(for 0.01, 0.02, 0.05, 0.1, 0.2, 0.4, 1, 1.5, 3, 6,10,
25, 50, 100m, half inert, inert)
Sensitivity and Length scale selectable for Normal and
Cut Length Diagrams
(Sensitivity options : +500% / -100%, +400%/-100%, +200%/
- 100%, +100%, +50%, +25%, +12.5%, +6.25%;
Length Scale Options:
(for 25 m/min : 0.2, 0.5, 1, 2, 5 and 10m
for 50 m/min : 0.5, 1, 2, 5, 10 and 20 m
for 100 m/min : 1, 2, 5, 10, 20 and 50 m
for 200 m/min : 2, 5, 10, 20, 50 and 100 m
for 400 m/min : 5, 10, 20, 50, 100 and 200 m)
User selectable longitudinal zooming
Marking of deviations on Mass and Hairiness diagrams
Spectrogram( Wavelength range 1cm to 1280m)
Variance Length Curves (Cut lengths from 1cm to 400 m)
Three dimensional Spectrograms and Variance Length Curves
(upto 12 tests per page)
Frequency Distribution diagrams (Histograms) |
|
 |
| Application
Range |
All fibre
assemblies (sliver, roving and yarn) containing staple fibres
from approx. 4 tex to 12ktex approx. (approx. 0.05 Nec to 150
Nec)
Yarn form is only Spun yarn. |
 |
| Measurement
Principle |
| Mass
variation |
Capacitance |
| Hairiness
|
Optical
(LASER) |
| Nep
Classification |
Optical |
| Actual
Count |
Mass |
|
 |
| Basic
Installation |
Basic Tester
(evenness)
PC
Printer |
 |
| Module
Options |
Hairiness
(for hair count and hairiness index)
Optical Nep (Nep classification into Process nep and seed coat
nep)
Actual Count (Linear density of sliver, roving and yarn)
Auto Cop (For automatic laying in of yarn into tester module)
Premier CYROS (Fabric simulation system) |
 |
| Testing
Speed |
|
25,
50, 100, 200, 400 m/min or yd/min (m/min or yd/min user selectable) |
 |
| User
Interface |
| Reports
|
All
measured characteristics in numerical and graphical format |
| Front
End Language |
English |
|
 |
| Dimensions |
Top
View |
Front
View |
 |
 |
| (All
dimensions are in mm) |
|
| |
| Power |
| Consumption |
1.5
KW |
| UPS
(on-line) |
2KVA
Single Phase |
|
 |
| Compressed
Air |
| Compressor
+ Drier |
6
bar |
| Consumption |
16m3
per hour |
|
 |
| Ambient
Conditions |
| Relative
Humidity |
65
± 2% |
| Temperature |
27
± 2° C for tropical countries
20 ± 2° C for temperate countries |
|
 Note:
Technical Specifications subject to change without notice |
|
|